Add Logger.rebuild()
Method
#189
Add Logger.rebuild()
Method
#189
Conversation
Whoops, forgot to update docs and type definitions. I added two commits to do that. I’m also noticing that it doesn’t look like Travis is in use any longer, or at least there are no CI checks showing up on this PR. Should we add a GitHub Actions workflow since Travis doesn’t really have a free-for-open-source plan anymore? |
lib/loglevel.js
Outdated
self.setLevel(level, false); | ||
defaultLevel = normalizeLevel(level); | ||
if (currentLevel == null) { | ||
self.rebuild(); |
There was a problem hiding this comment.
Choose a reason for hiding this comment
The reason will be displayed to describe this comment to others. Learn more.
I'm not clear why the defaultlevel logic everywhere needs to change to implement this, can you clarify that? It seems without changing this, rebuild should be able to just call setDefaultLevel
on children and they would update as expected already.
There was a problem hiding this comment.
Choose a reason for hiding this comment
The reason will be displayed to describe this comment to others. Learn more.
Hmmm, I’m not totally sure what you are getting at here, can you clarify a bit? (What do you mean by “the defaulLevel logic everywhere?”)
The problem I encountered going into this is that, under the hood, setDefaultLevel()
calls setLevel()
, and currentLevel
is whatever level the logger is at. BUT that means you can’t tell the difference between a case where the logger is taking its level from its parent vs. a case where a user has explicitly set the logger’s level. There were three solutions that I could think of for that:
-
Have
currentLevel
be the explicitly set level (or null/undefined if not set delegating to the parent’s level) and havedefaultLevel
represent the parent’s level (since we don’t have a reference to the parent). This is what I did because it seemed most straightforward to me, logic-wise. -
Have a new private variable named
hasExplicitLevel
or similar that indicates whethercurrentLevel
comes from a user’s call tosetLevel()
(if true) vs. if it came from the parent logger (if false). -
Have a logger keep a reference to its parent and drop the
defaultLevel
private variable. This has an issue wheregetLevel()
might return something that doesn’t match the actual current behavior (if a parent’s level has changed but this logger has not been rebuilt).
(That said, I suspect most of the above is probably clear to you, and I’m missing what you’re getting at.)
There was a problem hiding this comment.
Choose a reason for hiding this comment
The reason will be displayed to describe this comment to others. Learn more.
I think this should also applies to setDefaultLevel
though.
Reading the code, I think the current model implemented there is that 'something persisted' means that the value was overridden (and so shouldn't be changed) and anything else means that the value is a default value which should change when the default level changes.
We shouldn't change that existing logic for default levels (whether or not it's a good design, it's a breaking change that would unexpectedly change what's logged by people's applications).
I think the same logic should simply apply for the new rebuild API: if the pre-existing setDefaultLevel logic would modify the level, then rebuilding should modify the level.
In a future version we could re-evaulate this, and in that case I think there's a good argument for explicitly tracking whether the level was set manually or not, but for now I think we have to stick with the existing behaviour.
There was a problem hiding this comment.
Choose a reason for hiding this comment
The reason will be displayed to describe this comment to others. Learn more.
Reading the code, I think the current model implemented there is that 'something persisted' means that the value was overridden (and so shouldn't be changed) and anything else means that the value is a default value which should change when the default level changes.
I guess I’d argue that leaning on persistence is already problematic, since it doesn’t work in environments that have no persistence mechanism (e.g. Node, Bun, an iframe
with a lot of sandboxing options turned on, etc.). It means this happens, which sure feels like a bug to me:
var child = log.getLogger("test");
child.getLevel(); // 3 (WARN)
child.setLevel("TRACE");
child.getLevel(); // 0 (TRACE), good!
child.setDefaultLevel("DEBUG");
child.getLevel(); // 1 (DEBUG), seems bad!
Or more saliently, once there’s a rebuild()
method:
log.getLevel(); // 3 (WARN)
var child = log.getLogger("test");
child.getLevel(); // 3 (WARN), it inherited, good.
child.setLevel("TRACE");
child.getLevel(); // 0 (TRACE), good!
log.rebuild();
child.getLevel(); // 3 (WARN), seems bad that rebuilding changes the
// child's level after you've explicitly set it.
I suppose this is, very subtly, breaking; the question is whether the current behavior is a bug (my view, and hence why it is OK to “fix” as a byproduct of this) or is just what it is. I think most people’s mental model here is what I’m doing in this change and so wouldn’t be surprised by it.
There was a problem hiding this comment.
Choose a reason for hiding this comment
The reason will be displayed to describe this comment to others. Learn more.
There is also a test that models the above scenario:
loglevel/test/multiple-logger-test.js
Lines 175 to 182 in 4539639
it("should not change a child's explicitly set level even if un-persisted", function(log) { | |
log.setLevel("TRACE"); | |
var newLogger = log.getLogger("newLogger"); | |
newLogger.setLevel("DEBUG", false); | |
log.rebuild(true); | |
expect(newLogger).toBeAtLevel("DEBUG"); | |
}); |
I feel like it is clear to me that that test should always succeed (and therefore needs this change, or one of the similar things I enumerated above).
There was a problem hiding this comment.
Choose a reason for hiding this comment
The reason will be displayed to describe this comment to others. Learn more.
Ugh, looked back at the discussion when I originally added setDefaultLevel()
, and I am definitely wrong. “Default’ was probably a confusing name choice (my fault!) and I was over-focused on the browser context at the time. Anyway, I had lost track of the fact that setDefaultLevel()
was originally intended to be a way to say “set the level unless you’ve loaded saved configuration info from somewhere,” not “set the level if one hasn’t been explicitly set otherwise” (which is how I was thinking of it when I wrote this PR). The idea was that setDefaultLevel()
was for built-in config in your app, and setLevel()
was only for runtime reconfiguration by users (e.g. a dev setting it in their console, some preference a user might adjust, a CLI flag).
Obviously I need to re-do this. setDefaultLevel()
might not have been well designed (my fault!), but it is working as designed and is far too well baked to change, as you noted.
I think the same logic should simply apply for the new rebuild API: if the pre-existing setDefaultLevel logic would modify the level, then rebuilding should modify the level.
I don’t think this is quite right, though. With the right definition for setDefaultLevel()
(above), it seems like it obviously qualifies as explicitly setting the logger’s level just as much as setLevel()
does. Using either one means the logger’s level shouldn’t be influenced by its parent anymore.
That is:
log.setLevel("WARN");
var child1 = log.getLogger("child1");
child1.setLevel("ERROR");
child1.getLevel(); // ERROR
var child2 = log.getLogger("child2");
child2.setDefaultLevel("ERROR");
child2.getLevel(); // Let's assume ERROR and something was not previously saved
var child3 = log.getLogger("child3");
child3.getLevel(): // Let's assume it WARN because nothing was previously saved
log.methodFactory = function() { ... }
log.setLevel("TRACE");
log.rebuild();
// So the levels should now be:
// log = TRACE (we just set it)
// child1 = ERROR (was set with setLevel)
// child2 = ERROR (was set with setDefaultLevel)
// child3 = TRACE (was never set, so inherits the change from the parent)
Having rebuild()
call setDefaultLevel()
on child loggers would make child2
be at TRACE instead, and that’s where I don’t think it quite matches what setDefaultLevel()
was designed to do. @pimterry what do you think about this?
This also makes it a bit ambiguous what resetLevel()
should do. As coded today, calling it on the children would change child1
to TRACE and child2
would remain at ERROR
. I think that’s probably fine — it resets from the persisted level to the logger’s expected level — but I can imagine people expecting it clears any level info on the logger in favor of inheriting from the parent instead.
There was a problem hiding this comment.
Choose a reason for hiding this comment
The reason will be displayed to describe this comment to others. Learn more.
Hmm, this is a good & complicated question. I've spent a few days twiddling at it, and I'm really not sure what's best to be honest! I can think of arguments for quite a few different behaviours here, and it's very hard to classify which is 'right' objectively.
The output you suggest is reasonable though, and we can do it with minimum impact to any other logic, so let's go that way. I can see how the default behaviour is currently odd and muddies the water, but I think there is a use case for directly controlling top-level and child default levels, and that would be hard to do independently otherwise if the parent levels could override default levels as I was proposing.
To model this, I think in effect we have three states. Either the level is set explicitly (=persisted, in our current model) or it's set as a default level, or it's an unset inherited level.
In that model, a parent set(Default)Level overrides any other level, and should be inherited by all children who are inheriting the current level when rebuilt (and potentially later this should happen automatically). Calling either setLevel or setDefaultLevel on the child should move them from 'inherited' to one of the other two states, so that future parent changes & rebuilds never affect them.
We could track that model by adding just a single extra private boolean to track this 'unset' state, similar to your hasExplicitLevel
suggestion. If false, rebuild would override the level. It'd be set to true by setLevel, by setDefaultLevel, and by loading from a persisted level. resetLevel is tricky yes, but I agree that to match the current design it shouldn't unset it - effectively meaning that rebuild only ever affects loggers that have never ever been configured (which seems fine for what we're doing right here).
That would match your expected results above. It also requires nearly no changes to any other existing functionality, so we can mostly put getLevel & setDefaultLevel back as they were. The current set
methods just need to add logic to set their flag to true when called.
What do you think?
There was a problem hiding this comment.
Choose a reason for hiding this comment
The reason will be displayed to describe this comment to others. Learn more.
That makes sense and sounds good to me. I’ll get to work on that.
There was a problem hiding this comment.
Choose a reason for hiding this comment
The reason will be displayed to describe this comment to others. Learn more.
OK, this should be solved. I kept getting myself twisted up in the logic with the boolean, so I wound up refactoring this as 3 private variables. LMK know if you find this too confusing and I will refactor some more, but it felt much easier to comprehend for me:
inheritedLevel
is a cache of parent logger's level (orWARN
for the root logger). This is always set to something valid.defaultLevel
is the default level that has been set for this logger. It may be null (unset).userLevel
is the level that has been set for this logger via persistence or viasetLevel()
. It may be null (unset).
The current/effective level of the logger is userLevel OR defaultLevel OR inheritedLevel
.
This seemed like a more straightforward model of what’s going on, and the conceptual order of precedence is relatively obvious. There's no boolean or other state that is modifying how the levels behave based on what methods have been called in what contexts (resetLevel()
was causing me subtle problems, although after the above renaming, I am pretty sure I could switch back to having the boolean and get it right this time).
The other thing worth noting here is that I opted to have child loggers reach up to their parent to get the parent’s level, where I previously had the parent updating the children’s levels. Based on the discussion here, we would have had to add a special public method for the parent to call, which seemed bad. So I flipped it around.
(Side note: since we only have one level of children right now, the children can just grab the parent level from defaultLogger
. In some hypothetical future with a deep hierarchy of loggers, each logger will need to hold a reference to its parent.)
Thanks for this! Definitely looks like the right direction. I think there's some tweaks to make but we're on the right road and I agree it'd be nice to fix this up 👍 |
@pimterry Just a quick re-up on the above question. Since #190 landed, I think this should be pretty easy to do (and I am happy to do the work; just let me know). |
8881ce9
to
4539639
Compare
Logger.rebuild(includeChildren)
MethodLogger.rebuild()
Method
Sorry I missed that - yes, Travis is indeed dead, I'd be extremely happy to move to GitHub Actions if you want to set that up. |
This implements a new `Logger.rebuild(includeChildren)` method that does the actual work of replacing logging methods on a logger and, optionally, on child loggers. The goal is to make adding plugins (or otherwise changing the method factory) easier by giving users a way to update any child loggers that have already been declared, solving the need for careful declaration ordering as described in pimterry#187. In the ideal case, plugin developers will call this method automatically when their plugin is attached to a logger so users don't have to worry about it at all.
Fixes pimterry#187.
I rebased this work on top of pimterry#190, which means the tests now run in Jasmine 2.x, which treats error strings differently from error objects in `expect(...).toThrow(...)`, so this needed some updating.
This moves the non-recursive logic into a private method and makes the public `logger.rebuild()` method always recursive, per PR review.
See discussion in pimterry#189 (comment)
This changes the internal implementation to have three "level" variables, since I kept getting myself twisted up in knots with the idea of using a boolean. This made the logic much clearer for me: - `inheritedLevel` is the last known level from the logger's parent (or WARN for the root logger). This is always set to something valid. - `defaultLevel` is the default level that has been set for this logger. - `userLevel` is the level that has been set for this logger via persistence or via `setLevel()`. (This is similar to what was `currentLevel`, but not quite the same.) The effective level of the logger is just `userLevel OR defaultLevel OR inheritedLevel`.
4539639
to
4cd061f
Compare
Keeping these separate was unnecessarily confusing.
Alright, this should be ready for another review (and maybe to land). See my replies to the previous review comments for an update on the architecture here: #189 (comment) I added more comments, which pumps up the un-minified size a bit:
|
Thanks, I agree that 3 variable model looks cleaner, and I'm happy this pulls together the rebuild logic without changing the existing code too significantly. Thanks for all your hard work to make this and the other PRs happen. It's really tidied up the project and should be a great fix to help others who might be affected by #187 and similar confusion. Great stuff 👍. I'll do some last testing & checks locally and then publish a new release with these changes included soon. |
Awesome! 🙌 I’ll finish up with a commit that updates the contributing instructions as mentioned in #191 (comment). |
This resolves #187 by adding a new
Logger.rebuild(includeChildren)
method, which takes care of using themethodFactory
to update all the logging methods according to the current level. If theincludeChildren
argument is set totrue
and the method is called on the root logger, it will recursively rebuild all the child loggers (it isfalse
by default, but in some future v2, it should probably be changed totrue
).The
includeChildren
argument is mainly useful for two cases:When applying a plugin or modifying the logger’s
methodFactory
, it can be used to update previously existing child loggers, so you can divorce logger configuration code from logger declaration code. Ideally, plugin developers will call this from their plugin’s apply/register/whatever code. But a user could call it directly if a plugin developer does not.When changing the level on the root logger and you want that new level to apply to already existing child loggers (that you haven’t called
setLevel()
on and that didn’t have persisted levels). This essentially lets you treat a logger’s “default” level as if it means “whatever my parent/root logger’s current level is.”So in #187, the example problem code could be updated slightly to make everything work right:
Other Notes
In the discussion on Why do I have to configure the log in every typescript file? #187, we talked about calling this
rebuildLogger()
. I named itrebuild()
here because I thought that was just as clear and a bit more concise, but I’m happy to change it if you’d prefer.I made a small note in the code that
includeChildren
should default totrue
in some future v2 of the library. As discussed in Why do I have to configure the log in every typescript file? #187, havingsetLevel()
affect pre-existing child loggers is probably the right ideal, but might cause subtle breakage, so for now I just maderebuild()
only affect the current level by default. Flipping the default in the future will also affect the behavior ofsetLevel()
andsetDefaultLevel()
since they userebuild()
internally.Another option here is to make the default
true
but havingsetLevel()
andsetDefaultLevel()
call it withfalse
(solog.rebuild()
affects child loggers by default, butsetLevel()
andsetDefaultLevel()
do not). I think either way would probably be fine. 🤷There are a few subtle side-effects here:
The
currentLevel
private variable used to always be a valid level. It no longer is — you should always calllogger.getLevel()
to get the current level. (defaultLevel
will always be set and valid;currentLevel
will only be set ifsetLevel()
was explicitly called or a persisted level was loaded.) This shouldn’t affect the public interface at all, and I’ve made sure all internal callsites do the right thing.setLevel()
throws aTypeError
instead of astring
for invalid input. I don’t think this should really be an issue, and it arguably improves errors slightly (IMO throwing or rejecting with things that aren’t instancesError
or a sub-type is problematic). But I can change it back if you prefer.