# Geothermal Combined Heat and Power Problem using a Thermal Drawdown Reservoir Model and BICYCLE Economic Model and
# Solid Sorbent Direct Air Capture powered by geothermal
# Based on Example 3 description: This example problem considers an EGS reservoir at 3.1km depth.
# The heat is used in a combined heat and power topping cycle model with double flash as
# topping cycle and electricity considered as the main product.
# But only lists those parameters that are different than their default values
Do S-DAC-GT Calculations, True
***Subsurface technical parameters***
*************************************
Reservoir Model,3, ---m/A Single Fracture Thermal Drawdown
Reservoir Depth,3.1, ---[km]
Number of Segments,1, ---[-]
Maximum Temperature,400, ---[deg.C]
Drawdown Parameter,.00002, ---[kg/s/m2]
Gradient 1,70, ---[deg.C/km]
Number of Production Wells,3, ---[-]
Number of Injection Wells,3, ---[-]
Production Well Diameter,8.5, ---[inch]
Injection Well Diameter,8.5, ---[inch]
Ramey Production Wellbore Model,0, ---Should be 0 (disabled) or 1 (enabled)
Production Flow Rate per Well,70, ---[kg/s]
Reservoir Volume Option,1, ---Should be 1 2 3 or 4. See manual for details.
Fracture Shape,1, ---Should be 1 2 3 or 4
Fracture Area,200000, ---[m2]
Number of Fractures,12, ---[-]
Fracture Separation,80, ---[m]
Injectivity Index,5, ---[kg/s/bar]
Water Loss Fraction,0.02, ---[-]
***Surface Technical Parameters***
**********************************
End-Use Option,31, ---CHP Topping Cycle with electricity as the main product
Power Plant Type,4, ---Double-Flash
Circulation Pump Efficiency,.80, ---[-]
***Financial Parameters***
**************************
Economic Model,3, ---BICYCLE Levelized Cost Model
Inflated Equity Interest Rate,.08, ---[-] Required for BICYCLE model
Combined Income Tax Rate,.3, ---[-] Required for BICYCLE model
Gross Revenue Tax Rate,0, ---[-] Required for BICYCLE model
***Simulation Parameters***
***************************
Print Output to Console,1, ---Should be 1 (to print) or 0 (to not print)
Time steps per year,10, ---[-]