Metrics

This document elaborates on the types of metrics available in ngx_wasm_module, how they are stored in memory, and how to estimate the amount of slab_size memory necessary for your use-case.

Table of Contents

Types of Metrics

In accordance with Proxy-Wasm specifications, a "metric" is either a counter, a gauge, or a histogram.

  • A counter is an unsigned 64-bit int that can only be incremented.
  • A gauge is an unsigned 64-bit int that can take arbitrary values.
  • A histogram represents range frequencies of a variable and can be defined as a set of pairs of ranges and counters. For example, the distribution of response time of HTTP requests can be represented as a histogram with ranges [0, 1], (1, 2], (2, 4], and (4, Inf]. The 1st range counter would be the number of requests with response time less or equal to 1ms; the 2nd range counter represents requests with response time between 1ms and 2ms; the 3rd range counter are requests with response time between 2ms and 4ms; and the last range counter are requests with response time bigger than 4ms.

Back to TOC

Name Prefixing

To avoid naming conflicts between Proxy-Wasm filters, the name of a metric is always prefixed with colon-separated metadata: pw:{filter_name}:. This means that a metric named a_counter inserted by a_filter will have its name stored as: pw:a_filter:a_counter.

Thus, the maximum length of a metric name configured via max_metric_name_length is enforced on the prefixed name and may need to be increased in some cases.

Back to TOC

Histogram Binning Strategies

Logarithmic Binning

By default, histograms use a logarithmic-binning strategy. This is the only available binning strategy when using the Proxy-Wasm SDK at this time.

As an example of logarithmic-binning, take the histogram with ranges (i.e. "bins") [0, 1] (1, 2] (2, 4] (4, Inf]: each bin's upper-bound is growing in powers of 2: 2^0, 2^1, and 2^2. In logarithmic-binning, a value v being recorded is matched with the smallest power of two that is bigger than v. This value is the upper-bound of the bin associated with v. If the histogram contains or can contain such a bin, then its counter is incremented. If not, the bin with the next smallest upper-bound bigger than v has its counter incremented instead.

In ngx_wasm_module, logarithmic-binning histograms are created with one initialized bin with upper-bound 2^32. The counter for this bin is incremented if it is the only bin whose upper-bound is bigger than the recorded value.

When a value v is recorded and its bin does not yet exist, a new bin with the upper-bound associated with v is initialized and its counter is incremented.

A logarithmic-binning histogram can contain up to 18 initialized bins.

Back to TOC

Custom Binning

Through the Lua FFI library provided with this module, histograms can also be created with a fixed set of bins with user-defined upper-bounds. These histograms store values exactly like the logarithmic-binning ones, except the number of bins and their upper-bounds are user-defined and pre-initialized.

A custom-binning histogram can contain up to 18 bins (17 user-defined bins + one 2^32 upper-bound bin). Custom-binning histograms cannot be expanded with new bins after definition.

Back to TOC

Memory Consumption

The space occupied by a metric in memory contains:

  1. Its name.
  2. Its value.
  3. And the underlying structure representing the metric in the shared key-value store memory (see slab_size).

While the key-value structure has a fixed size of 96 bytes, the sizes of name and value vary.

In memory, the value of a counter or gauge occupies 8 bytes + 16 bytes per worker process. The value size grows according to the number of workers because metric values are segmented across them: Each worker has its own segment of the value to write updates to. When a metric is retrieved, the segments are consolidated and returned as a single metric value. This storage strategy allows metric updates to be performed without the aid of shared memory read/write locks at the cost of 16 bytes per worker.

Histogram values have a baseline size of 8 bytes + 24 bytes per worker process. However, histograms also need extra space per worker for bins storage. Bins storage costs 4 bytes + 8 bytes per bin. Thus, a 5-bin histogram takes: 8 bytes + (24 + 4 + 5*8), so 68 bytes per worker.

As such, in a 4-workers setup, a counter or gauge whose name is 64 chars long occupies 168 bytes, and a 5-bin histogram with the same name length occupies 408 bytes. A 18-bin histogram with the same length name occupies 856 bytes.

Back to TOC

Shared Memory Allocation

Nginx employs a shared memory allocation model that enforces allocation size to be a power of 2 greater than 8; nonconforming values are rounded up, see Nginx shared memory.

For instance, this means that an allocation of 168 bytes ends up occupying 256 bytes of shared memory. This should be taken into consideration when estimating the total space required for a group of metrics.

Back to TOC

Nginx Reconfiguration

If Nginx is reconfigured with a different number of workers or a different slab_size value, existing metrics need to be reallocated into a new shared memory zone at reconfiguration time. This is due to the metric values being segmented across workers.

As such, it is important to make sure that the new slab_size value is large enough to accommodate existing metrics, and that the value of max_metric_name_length is not less than any existing metric name.

Back to TOC